Ensure equipment reliability, reduce downtime and eliminate safety risks.

By Dan McCarty

Gas sampling equipment is one of the most widely used tools in medical, food processing, brewing and landfill gas (LFG) monitoring applications. Units range from gas extraction meters, gas analyzers and carbon dioxide (CO2) analyzers, to nitrous oxide (N2O) and carbon monoxide (CO) analyzers. Proper equipment calibration is essential to ensure sample accuracy and equipment reliability, reduce equipment downtime, and eliminate safety risks.

Proper Calibration Ensures Measurement Samples are within Analyzer Specifications

Proper calibration ensures that the measurement samples being taken are within the analyzers’ specifications and are as accurate as possible. Calibration verifies that equipment and workspaces are within the desired gas ranges and not out of control. If users conduct a gas check with an analyzer and the ranges are not as expected, they can identify the issue and make necessary adjustments. This helps them maintain regulatory compliance and maximize the equipment’s effectiveness.

Calibration is also important for workplace safety. For example, gas analyzer units are used to evaluate the amount of landfill gas flowing from an LFG well. Amounts above certain thresholds can cause environmental and health hazards for those working nearby.

If gas analyzer units detect methane above recommended threshold levels, technicians know they need to adjust the wells to regulate the methane by opening up the wells or making other adjustments to tune the well. Since the Environmental Protection Agency (EPA) regulates LFG emissions gas, analyzer equipment accuracy plays a big part in maintaining landfill compliance.

Calibration Procedure Basics

Equipment should be calibrated at least annually; in some cases, bi-annual calibration is recommended. A rigorous calibration process should include a robust quality assurance/quality control process filled with manual and automated checks to verify the calibration was done precisely. When repairs are necessary, expert technicians should seek the root cause to correctly repair and service the instrument. Make sure the calibration laboratory is fully certified to ISO/IEC 17025:2005 requirements for carrying out calibrations.

For example, when an analyzer needs calibration and/or repair, the unit should be placed in a calibration chamber, going through an automated programming process. First, the process verifies the type of analyzer and exactly what is needed to calibrate the specific model. Next, it will perform several pre-calibration tests of the equipment. Then, the analyzers are purged with gas to obtain a baseline reading and reach a stabilization period before the actual gas calibration process beings.

The gas calibration technician pushes a highly graded research gas through the analyzer at all ranges needed by each model to make sure each one reads within the specifications. The gases used, special mixtures contained in high-pressure compressed gas metal cylinders, should be certified by the National Institute of Standards and Technology (NIST). For example, for EPA’s gas protocol, the gas is made by specialty gas companies that follow an EPA document to blend and analyze individual mixtures using NIST guidelines for their certification.

As that is occurring, a programming process is implemented to save the data the chamber is writing and reading to the electronics in the analyzer. The chamber performs a thermal test and increases the temperature to verify that the analyzer will read the correct parts per million (PPM) of the gases when the environmental changes occur. This is important because gases can change their properties as a result of these environmental changes.

Once the thermal check is verified as effective, a final programming step is taken within the analyzer and the chamber’s computer. After the electronics have finalized the programming, calibration technicians run a verification check. This double-checks that the analyzer is reading gases correctly and that the programming was performed successfully. This step basically duplicates all the prior actions to determine if the unit sustains its readings.

Tips for Keeping Equipment Properly Calibrated 

There are a few tips that will ensure equipment remains properly calibrated:

  • First and foremost, always follow all manufacturers’ guidelines and recommendations concerning equipment use and maintenance.
  • Seek out and use preventative maintenance kits and protective filters, which live inside the case and protect the equipment from damage. One example is water trap filters, which can protect against condensation in the line or at sites with a high water table. This condensation can have a negative effect on equipment accuracy. Water trap filters that provide built in gas moisture removal are also widely used in medical device analyzers, including those designed to monitor CO2 for verification of incubators in in-vitro fertilization, medical research and pharmaceutical applications. The use of filters is essential for ensuring data accuracy.
  • Conduct field calibration at least once a day. This ensures that the analyzer is reading precisely for the specific application and verifies the unit is reading correctly each time with the factory settings. The field calibration is done using a kit containing a small hand-held 24-inch gas canister and a regulator inside a special carry case. Users hook up their equipment to the canister with the special concentrated blend that uses the gas ratio specific to their application. One of the most widely used is a kit for landfills, in which the gas is 50 percent methane and 35 percent CO2.

Tracking Required Calibration

The best practice is to keep track of equipment and send it in before it is due, rather than when prompted. For example, your analyzer should have a device information screen that indicates when service is due. If users operate the device after this due date, the analyzer will display a prompt on the self-test screen that comes up each time the analyzer is powered on. Users would have to press a key (skip button) to continue past the screen when prompted that service is overdue.

With the level of investment many companies make in these analyzers, it makes good economic sense to stay on top of calibration requirements. Maintain calibration schedule records for all of your equipment. These records are required for accreditation purposes. Hard copy and electronic copies of equipment service history are kept at your service provider’s location until the end of life for all equipment sold.

Gas analyzers play a key role in important environmental and medical processes. Maintaining timely and proper calibration ensures that they can contribute to the fullest extent and avoid wasted time and effort.

Dan McCarty is Calibration/Service Manager for QED Environmental Systems (Dexter, MI). Responsible for all aspects of the day-to-day running of the gas analyzer service department, he prioritizes workload, report service progress and key production indicators, facilitating all operational concerns and issues as applicable. For more information, visit www.qedenv.com.